How the panels seal and lock
Three panels stack tongue into groove. EPDM strips seal every panel joint, gasketed post channels seal both faces of the stack, and two clamps per opening press the whole stack down onto the sill foam.
Engineering documentation for the WDS-35T deployable aluminum flood barrier. Dimensioned drawings of every component, material specifications and the summary of a third-party witnessed performance test to BS 851188-2. Prepared for property managers, engineers, architects and general contractors who need to specify or approve a flood barrier for a building.
Sample sheet: barrier panel
What the full package contains
- System overview, component specifications, witnessed test summary and general notes
- Barrier panel: profile section and panel types
- Panel stack assembly and protection heights by panel count
- Side post: 80 x 52 mm section and wall-mounted detail
- Middle post: 80 x 100 mm section and back support bracket
Five landscape sheets in engineering format with title block, dimensions in millimeters and inches, and notes for installation on walls, frames and slabs.
Component specifications
| Barrier panel | Extruded aluminum 6063-T5, anodized. 220 mm [8.66 in] high x 35 mm [1.38 in] thick, 2 mm wall, multi-cell hollow profile with top hook and bottom groove. |
|---|---|
| Panel types | Top panel with two U-caps and two EPDM water strips; middle panels with two EPDM water strips each; bottom panel with EPDM bottom foam at the sill. |
| Side posts | 80 x 52 mm [3.15 x 2.05 in] section, 4 mm wall, side-wall mounted, EPDM seal lips in the channel, compression bolt at the top. |
| Middle post | 80 x 100 mm [3.15 x 3.94 in] double-channel section with 8 mm center web and rear back support bracket anchored to the slab. Used on wide openings. |
| Protection height | 220 mm per panel. Standard WDS stack of 3 panels = 660 mm [26 in]. Tested to 5 panels (1002 mm water head). |
| Spans | Single door up to 4 ft, single garage up to 9 ft, double garage up to 18 ft with one middle post; wider openings with additional middle posts. |
Witnessed performance test
A 6.0 m x 1.12 m barrier (15 panels, 2 side posts, 2 middle posts) was tested over three full cycles, 80 hours in total, with the test witnessed by SGS (report NJINSCS2600257 Rev03, May 2026). Reference standard BS 851188-2:2019+A1:2021.
| Water heights | 334 mm, 668 mm and 1002 mm [13, 26 and 39 in], each held for one hour in every cycle |
|---|---|
| Leakage limit | Less than 40 L/h per meter of barrier |
| Leakage measured | 0.02 to 0.20 L/h per meter across all heights and cycles |
| Impact test | 50 kg [110 lb] weight at 334 mm, two impacts: 0 mm deformation, no increase in leakage |
| Result | Satisfactory |
Warranty
5-YEAR WARRANTY. Panels, posts and hardware: 5 years. Seals: 3 years. Installation: 1 year when installed by Water Defense.
This warranty covers defects in materials and workmanship. If a part is defective, we repair or replace that part. Installed by you or your contractor? The product coverage above still applies to manufacturing defects. Installation workmanship is covered by your installer.
Not covered: misuse or abuse; water rising above the barrier's design height; loads beyond the design specification; unauthorized modifications or attachments; damage in storage or handling; deployment that does not follow the installation guide.
Request the installation guide or user manual: write to info@waterdefense.us or call (786) 783-6080.
WDS-35T Installation Manual
For installers and dealers. Version 0.6, English and Spanish: bracket layout and anchoring, approved substrates, the full step-by-step installation and the handover checklist. This manual is not published openly: complete the form (all fields are required) and we will text you a private download link to your mobile phone, valid for 7 days.
Panel Length Options
How do you want the panels cut? This one-page guide shows the two cut options for your opening (Option 1 and Option 2). It is an open document: no form, no sign-up.
Request the full technical package
We send the complete 5-sheet PDF by email, usually within one business day, together with any project-specific detail you need (opening widths, post spacing, anchoring for your substrate).